2Deparment of Radiation Oncology, Acıbadem Altunizade Hospital, İstanbul-Türkiye
3Deparment of Radiation Oncology, University of Health Sciences, Van Training and Research Hospital, Van-Türkiye DOI : 10.5505/tjo.2022.3740
Summary
OBJECTIVEIt is aimed to compare the hybrid radiotherapy (RT) plans according to three-dimensional field-in-field (FIF), intensity-modulated RT (IMRT), and volumetric-modulated arc therapy (VMAT) techniques in RT applied to the whole breast volume after breast-conserving surgery.
METHODS
Based on the simulation images of 31 consecutive patients who received whole breast RT, a dose of 50 Gy
(25 fractions) was prescribed to the planned treatment volume (PTV) with 6 MV X-rays, five new plans
were created, respectively (FIF, VMAT, IMRT, H-VMAT, and H-IMRT). Homogeneity criteria for PTV,
volume-dose criteria for peripheral critical organs, and MU values of the plans were evaluated separately
for each plan. Subgroup analyses were performed for the left- and right-sided patients.
RESULTS
Both hybrid plans produced a more homogeneous plan at the target volume compared to the other
three techniques (HI; 0.14, 0.14, 0.16, 0.12, and 0.13, p<0.001, respectively). Again, smaller values for
D2% were obtained with both hybrid techniques (53.25, 53.24, 53.8, 52.41, and 52.47 Gy, respectively,
p<0.001). The mean heart dose for the left-sided irradiations was 3.54, 3.40, 4.33, 3.49, and 3.79 Gy for
the five techniques, respectively (p=0.029). Compared with FIF with the other four techniques for the
left-sided irradiations, the LAD D 10% value was significantly reduced (p<0.001).
CONCLUSION
Hybrid plans provide a more homogeneous dose distribution compared to the use of other techniques
alone, while at the same time, it allows reducing the ipsilateral lung and heart doses.
Introduction
Radiotherapy (RT) is a part of multimodal treatment for breast cancer. Equivalent results to mastectomy have been obtained with the application of RT after breast-conserving surgery in early-stage breast cancer. [1,2] Today, the 15-year survival rate for early-stage breast cancer is reported to be 80%.[1] This makes it more important to keep critical organ doses to a minimum in breast cancer RT. Because long-term side effects of RT, such as bad cosmetics due to skin fibrosis, secondary cancers, and coronary diseases, are more likely to occur.[3]The breast is an organ that shows great geometrical variations on a patient basis. Many factors, such as breast size, shape, surface irregularities, and chest wall structure, directly affect RT planning.[4] This makes it difficult to provide a homogeneous dose distribution during RT planning. Classically, two tangential fields with mutual wedges were used in the three-dimensional period in whole breast RT planning. It was not entirely possible to control hotspots with this technique. However, with the development of the field-in-field (FIF) technique, it has become feasible to close the hotspots in the tangential areas with multi-leaf collimator (MLC) leaves and to provide dose modulation. Subsequently, it has been shown that dose homogeneity is increased with the intensity-modulated RT (IMRT) technique, and thus, a significant reduction in acute and chronic side effects is achieved.[5,6] It has been reported that there is a decrease in acute skin reactions and better long-term cosmetic results are obtained with IMRT.[5] Similarly, it was found that volumetric-modulated arc therapy (VMAT) provides dose homogeneity equivalent to IMRT and is better at protecting critical organs. [7] However, in IMRT and VMAT techniques, a more homogeneous dose distribution is achieved and adjacent critical structures are better preserved, while the volume of the low-dose area and the amount of dose received by the contralateral organs increase compared to the FIF technique. Increasing the low-dose area is associated with an increased risk of secondary cancer in the long term.[8] On the other hand, since IMRT and VMAT are much more complex techniques than tangential irradiation, they cause an increase in workload during both planning and treatment implementation. Considering that 30% of patients treated in radiation oncology clinics have breast disease, the importance of this situation is better understood.[9] To overcome these problems and to combine the good points of each technique, the idea of hybrid planning was introduced. In this way, it aims to make more optimal and balanced RT plans by combining the FIF technique with IMRT or VMAT.[8-10]
In light of this information, the goal of our study was to compare FIF, VMAT, IMRT, H-VMAT (hybrid VMAT), and H-IMRT (hybrid IMRT) techniques in terms of dosimetric and treatment duration (MU) in all breast irradiations (without boost) using conventional fractionation.
Methods
Considering the difference in breast anatomy in the study, target volumes on computed tomography sections taken in the treatment position of 31 breast cancer patients (15 right and 16 left) with breast volumes in the range of 391.4-1901.6 cc, such as CTV, planned treatment volume (PTV), and critical organs; contralateral breast, ipsilateral lung, contralateral lung, and heart were contoured in accordance with Radiation Therapy Oncology Group protocols. Plans were made by ensuring that the 95% volume of the PTV received the 95% treatment dose (50 Gy [2 Gy/fr]). The 6 MV photon energy was calculated using the Analytical Anisotropic Algorithm (AAA) in the Eclipse treatment planning system (version 15.6). The configuration of the AAA model is based on the physical parameters determined by Monte-Carlo.[11]
Design of Plan
• During the planning of the FIF, two tangential areas
were opened to each other, the table angle was
not used, the hot dose zones formed in the PTV
were drawn automatically in the TPS, and a homogeneous
dose distribution was obtained by closing
the hot areas with the help of MLC by opening the
lower two areas have been done.
• VMAT, while determining the entrance and exit angles of the areas in their planning, was created to be the same as the entrance angles of the two tangential open areas. The fields were opened in a clockwise and counterclockwise direction, with two opposite arcs. A table angle of 30 degrees was not used and the two arcs are coplanar and each of the arcs is given collimator angel of 5 and 355 degrees, respectively.[12]
• IMRT was planned to have five fields. The table and collimator angle was not used. While determining the field angles, the localization of critical organ structures and the shape of the breast structure were taken into account, and patient-specific angles were determined for each patient.
• In the H-IMRT plan, a mixture of FIF and IMRT techniques was used. FIF technique (26 Gy/13f) was used for the first 13 fractions, and IMRT (24 Gy/12f) for the later 12 times. A total dose of 50 Gy (25 fractions) has been prescribed for H-IMRT plans.
• In the H-VMAT plan, a mixture of FIF and VMAT techniques was used. FIF technique (26 Gy/13f) was used for the first 13 fractions and VMAT (24 Gy/12f) for the later 12 times. A total dose of 50 Gy (25 fractions) has been prescribed for H-IMRT plans. The plan designs of five different RT plans made in this study on a single patient are given in Figure 1.
Evaluation of Plan
Dmean, D2, and D98 parameters were checked for PTV.
The formula suggested by ICRU 62 was used while calculating
the CI parameter, and the ICRU 83 formula
was used for the HI parameter.[13,14] In critical organ
structures, D40, D10, D5%, and Dmean values for the heart
dose, D10% value for LAD, D60%, D30%, D5%, and Dmean values
for the lung on the planned side, the parameters
were evaluated by looking at the D60% and Dmean values
for the lung, and the V5Gy and Dmean values for the
contralateral breast from the dose-volume histogram.
In addition, total MU values were calculated for each
plan. The results were transferred to the SPSS (IBM,
v17.0) program for statistical analysis and compared
with appropriate parameters or non-parametric tests.
Results
Both hybrid plans produced a more homogeneous plan in the target volume compared to the other three techniques (for HI FiF, VMAT, IMRT, H-VMAT, and H-IMRT, 0.14, 0.14, 0.16, 0.12, and 0.13, respectively, p<0.001). Again, both hybrid techniques were able to obtain smaller values for D%2 for 53.25, 53.24, 53.8, 52.41, and 52.47, respectively, p<0.001. There were no significant differences in homogeneity criteria for PTV between FiF, IMRT, and VMAT techniques (p=1, for pairwise comparisons). The mean dose in the ipsilateral lung was decreased by the VMAT and H-VMAT techniques (p=0.024). With the other four techniques, except for the FiF plan, the mean doses of both the contralateral lung and the breast increased significantly (for both, p<0.001). However, with the H-VMAT and H-IMRT planning, both the mean lung dose and breast dose of the contralateral side decreased compared to the VMAT and IMRT techniques. The mean heart dose for the left-sided irradiation was 3.54, 3.40, 4.33, 3.49, and 3.79 for the five techniques, respectively (p=0.029). With FiF, the LAD D10% value was significantly decreased in the left-sided irradiations with the other four techniques (p<0.001). On the other hand, in the right-sided irradiations, mean heart doses were significantly increased in the other four techniques compared to the FIF technique, while they were found to be lower with H-VMAT and H-IMRT compared to the VMAT and IMRT techniques (0.63, 2.61, 2.94, 1.56, and 1.78, p<0.001, respectively). MU values were found to be the lowest for FiF, while H-VMAT and H-IMRT planning decreased MU values compared to VMAT and IMRT techniques (p<0.001 for 235.95, 525.27, 933.59, 381.6, and 561.97, respectively). The results are shown in Table 1.Table 1 Statistical results of (a) FIF, (b) IMRT, (c) VMAT, (d) H-IMRT, and (e) H-VMAT planning
Discussion
With the FIF technique, which was developed after the three-dimensional conformal RT (3D-CRT) technique was applied using a mutually wedged area, a more homogeneous dose distribution is achieved, while the doses taken by critical organs can be significantly reduced.[15] However, large differences in breast sizes, geometric shapes, and surface irregularities prevent FIF planning from giving the same accurate results for each patient.[16] With the introduction of IMRT and VMAT techniques, this problem was solved to a large extent, while problems such as prolonged treatment time (increased MU) and increased low-dose area were encountered.[6,7] It has been shown that the hybrid planning idea developed on this basis can reduce the planning time while creating a plan of equivalent quality to IMRT.[17] In our study, protocols were created for planning FIF, VMAT, IMRT, H-VMAT, and HIMRT, and planning for the right- and left-sided breast cancer patients was done and compared dosimetrically.The lungs are the organs directly affected during breast irradiation, as they are located just below the breast tissue. Radiation-induced pneumonia is observed in approximately 10% of breast cancer patients, and fibrosis is observed in the lung region where X-rays are transmitted in 90%.[18] In the study of Fragkandrea et al.,[19] lung doses were shown to be directly related to radiation pneumonia and fibrosis. The mean lung dose in patients who did not show signs of pneumonia in computed tomography sections was 11.2 Gy, with a V20 Gy of 16.7%. While the D% value of 25% was reported as 14 Gy, 20.7%, and 23 Gy, respectively, in the group with pneumonia. The 3D-CRT technique was used in the study. In our study, mean ipsilateral lung doses were found to be 9.7 Gy, 8.8 Gy, 9.75 Gy, 9.2 Gy, and 9.7 Gy for FIF, VMAT, IMRT, H-VMAT, and HIMRT, respectively (p=0.024). D30% doses were determined as 6.2 Gy, 8.6 Gy, 10.2 Gy, 7.5 Gy, and 8.5 Gy, respectively (p<0.001). These results indicate that all techniques can be applied safely. However, H-VMAT was found to be superior to H-IMRT in terms of ipsilateral lung mean dose (p<0.001). There was no significant difference between VMAT and H-VMAT (p=0.886).
The heart is particularly affected during the left breast irradiation. Although the heart is largely outside the RT area in the right-sided irradiations, it was emphasized that there is no threshold dose for ischemic heart disease in the study of Darby et al.[20] According to this study, every 1 Gy increase in the mean heart dose increases the risk of ischemic heart disease by 7.4%. In our study, LAD and heart doses were evaluated separately for the right (n=15) and left (n=16) breast cancer patients. In the left breast patients, the LAD D 10% value was found to be 39.8 Gy, 22.2 Gy, 28.4 Gy, 31.4 Gy, and 33.5 Gy for FIF, VMAT, IMRT, H-VMAT, and H-IMRT, respectively (p<0.001). VMAT and IMRT provided an advantage in LAD doses compared to the FIF technique (p<0.001 and p 0.005, respectively). In addition, VMAT was found to be more successful in LAD preservation than the H-IMRT technique (p=0.002). The LAD D10% value in the right-sided patients was seen as zero for all patients. The mean cardiac doses for the left-sided patients were 3.5 Gy, 3.4 Gy, 4.3 Gy, 3.5 Gy, and 3.8 Gy, respectively (p=0.029); for the right-sided patients, it was determined to be 0.6 Gy, 2.6 Gy, 2.9 Gy, 1.6 Gy, and 1.8 Gy, respectively (p<0.001). The lowest mean heart doses were obtained with VMAT and H-VMAT in the leftsided irradiations. In the right breast RT, the FIF technique provides a significant advantage in terms of mean heart dose compared to all other techniques (p<0.001).
It has been reported that the risk of developing secondary cancers is approximately 2 times higher in the IMRT technique compared to 3D-CRT, due to the increase in the low-dose area. It has been emphasized that there will be an increase in the number of secondary cancers in the young population and the patient group with a long survival expectancy, but the risk ratio will remain constant.[21] However, there are also opposing views on this issue. In the study performed by Filippi et al.[22] on patients with mediastinal lymphoma, no difference was found between VMAT and 3D-CRT techniques in terms of secondary cancer risk (breast and thyroid). Despite the contradictory results obtained in studies in the literature, it is known that RT can have a carcinogenic effect in very small doses.[23] Therefore, care should be taken in terms of small dose baths during RT planning. In particular, the doses taken by the contralateral breast and lung must be controlled. Due to the increase in the number of RT fields and entry angles,[17] techniques such as IMRT and VMAT affect more normal tissues until they reach the target. The results obtained with the techniques applied in our study were also found to be compatible with this. The volume of V5Gy for the contralateral breast was 0.6%, 3.5%, 3.7%, 2%, and 2% for the FIF, VMAT, IMRT, HVMAT, and H-IMRT techniques, respectively (p<0.001). Similarly, the mean contralateral lung doses were 0.1 Gy, 1.7 Gy, 1.8 Gy, 0.9 Gy, and 0.8 Gy, respectively. The FIF technique provides a significant advantage over all other techniques for low-dose volume (p<0.001). Hybrid plans, on the other hand, significantly reduce low-dose volume compared to IMRT and VMAT techniques (p<0.001).
There was a statistically significant difference between the five techniques in terms of D2% for PTV. The dose received by 2% of the PTV for hybrid plans was lowest compared with the other techniques (respectively, 53.25, 53.24, 53.8, 52.41, and 52.47 Gy, p<0.001). A study showed that hybrid plans achieved optimal PTV coverage while avoiding hotspots in PTV volume. These results are in agreement with the results reported by Zheng et al.[24]
Complex techniques such as IMRT and VMAT cause an increase in the MU numbers of the planes. [25] Breast cancer is one of the most common types of cancer and accounts for 30% of patients in radiation oncology clinics.[9] Therefore, prolonged treatment and planning periods become an important workload for clinics. In our study, the mean MU values for FIF, VMAT, IMRT, H-VMAT, and H-IMRT were found to be 235, 525, 933, 381, and 561, respectively. The FIF technique was found to be significantly superior to all other techniques except H-VMAT (p<0.001). Hybrid techniques were found to be statistically significantly effective in shortening the treatment time (p<0.001).
Conclusion
All the techniques evaluated in the study can be used safely for breast irradiation. The FIF technique provides significant advantages over IMRT and VMAT in terms of treatment time and low-dose volume. On the other hand, VMAT and IMRT techniques seem to be superior in providing homogeneous dose distribution and protecting neighboring critical organs. It is possible to obtain more balanced and optimal RT plans by combining hybrid techniques with FIF and VMATIMRT techniques. For the selection of the appropriate technique, it is necessary to decide on a patient-specific basis according to the patient"s anatomical structure, breast volume, and clinical goals during planning. In situations requiring complex planning, hybrid techniques may be preferred to reduce the mean heart dose.Peer-review: Externally peer-reviewed.
Conflict of Interest: All authors declared no conflict of interest.
Financial Support: None declared.
Authorship contributions: Concept - H.S.C.; Design - H.S.C.; Supervision - H.S.C.; Funding - None; Materials - N.V.D.; Data collection and/or processing - S.Ç.S.; Data analysis and/or interpretation - E.Ş.; Literature search - N.V.D.; Writing - H.S.C.; Critical review - H.B.
References
1) Early Breast Cancer Trialists" Collaborative Group
(EBCTCG), Darby S, McGale P, Correa C, Taylor C,
Arriagada R, et al. Effect of radiotherapy after breastconserving
surgery on 10-year recurrence and 15-year
breast cancer death: meta-analysis of individual patient
data for 10,801 women in 17 randomised trials.
Lancet 2011;378(9804):1707-16.
2) Clarke M, Collins R, Darby S, Davies C, Elphinstone
P, Evans V, et al; Early Breast Cancer Trialists" Collaborative
Group (EBCTCG). Effects of radiotherapy
and of differences in the extent of surgery for early
breast cancer on local recurrence and 15-year survival:
an overview of the randomised trials. Lancet
2005;366(9503):2087-106.
3) Brownlee Z, Garg R, Listo M, Zavitsanos P, Wazer DE,
Huber KE. Late complications of radiation therapy for
breast cancer: evolution in techniques and risk over
time. Gland Surg 2018;7(4):371-8.
4) Balaji K, Subramanian B, Yadav P, Anu Radha C, Ramasubramanian
V. Radiation therapy for breast cancer:
Literature review. Med Dosim 2016;41(3):253-7.
5) Pignol JP, Olivotto I, Rakovitch E, Gardner S, Sixel
K, Beckham W, et al. A multicenter randomized
trial of breast intensity-modulated radiation therapy
to reduce acute radiation dermatitis. J Clin Oncol
2008;26(13):2085-92.
6) Donovan E, Bleakley N, Denholm E, Evans P, Gothard
L, Hanson J, et al; Breast Technology Group. Randomised
trial of standard 2D radiotherapy (RT) versus
intensity modulated radiotherapy (IMRT) in patients
prescribed breast radiotherapy. Radiother Oncol
2007;82(3):254-64.
7) Fogliata A, Seppälä J, Reggiori G, Lobefalo F,
Palumbo V, De Rose F, et al. Dosimetric trade-offs in
breast treatment with VMAT technique. Br J Radiol
2017;90(1070):20160701.
8) Balaji K, Yadav P, Balaji Subramanian S, Anu Radha C,
Ramasubramanian V. Hybrid volumetric modulated
arc therapy for chest wall irradiation: For a good plan,
get the right mixture. Phys Med 2018;52:86-92.
9) Farace P, Zucca S, Solla I, Fadda G, Durzu S, Porru S,
et al. Planning hybrid intensity modulated radiation
therapy for whole-breast irradiation. Int J Radiat Oncol
Biol Phys 2012;84(1):e115-22
10) Mayo CS, Urie MM, Fitzgerald TJ. Hybrid IMRT
plans--concurrently treating conventional and
IMRT beams for improved breast irradiation and reduced
planning time. Int J Radiat Oncol Biol Phys
2005;61(3):922-32.
11) Sievinen J, Ulmer W, Kaissl W. AAA photon dose calculation
model in Eclipse. Palo Alto, CA: Varian Medical
Systems; 2005.
12) Jin GH, Chen LX, Deng XW, Liu XW, Huang Y, Huang
XB. A comparative dosimetric study for treating leftsided
breast cancer for small breast size using five different
radiotherapy techniques: conventional tangential
field, filed-in-filed, tangential-IMRT, multi-beam
IMRT and VMAT. Radiat Oncol 2013;8:89.
13) International Commissions on Radiation Units and
Measurements. ICRU Report 62, prescribing, recording,
and reporting photon beam therapy (supplement
to ICRU report 50). Bethesda MD, USA: ICRU.
14) International Commissions on Radiation Units and
Measurements. ICRU83, prescribing, recording, and
reporting intensity-modulated photon beam therapy,
(IMRT). Journal of the ICRU 2010;10(1):Report 83.
15) Baycan D, Karacetin D, Balkanay AY, Barut Y. Field-infield
IMRT versus 3D-CRT of the breast. Cardiac vessels,
ipsilateral lung, and contralateral breast absorbed
doses in patients with left-sided lumpectomy: a dosimetric
comparison. Jpn J Radiol 2012;30(10):819-23.
16) Nakamura N, Takahashi O, Kamo M, Hatanaka S,
Endo H, Mizuno N, et al. Effects of geometrical uncertainties
on whole breast radiotherapy: a comparison
of four different techniques. J Breast Cancer
2014;17(2):157-60.
17) Descovich M, Fowble B, Bevan A, Schechter N, Park
C, Xia P. Comparison between hybrid direct aperture
optimized intensity-modulated radiotherapy and forward
planning intensity-modulated radiotherapy for
whole breast irradiation. Int J Radiat Oncol Biol Phys
2010;76(1):91-9.
18) Nishioka A, Ogawa Y, Hamada N, Terashima M, Inomata
T, Yoshida S. Analysis of radiation pneumonitis
and radiation-induced lung fibrosis in breast cancer
patients after breast conservation treatment. Oncol
Rep 1999;6(3):513-7.
19) Fragkandrea I, Kouloulias V, Mavridis P, Zettos A,
Betsou S, Georgolopoulou P, et al. Radiation induced
pneumonitis following whole breast radiotherapy
treatment in early breast cancer patients treated with
breast conserving surgery: a single institution study.
Hippokratia 2013;17(3):233-8.
20) Darby SC, Ewertz M, McGale P, Bennet AM, Blom-
Goldman U, Brønnum D, et al. Risk of ischemic heart
disease in women after radiotherapy for breast cancer.
N Engl J Med 2013;368(11):987-98.
21) Hall EJ, Wuu CS. Radiation-induced second cancers:
the impact of 3D-CRT and IMRT. Int J Radiat Oncol
Biol Phys 2003;56(1):83-8.
22) Filippi AR, Ragona R, Piva C, Scafa D, Fiandra C,
Fusella M, et al. Optimized volumetric modulated arc
therapy versus 3D-CRT for early stage mediastinal
Hodgkin lymphoma without axillary involvement: a
comparison of second cancers and heart disease risk.
Int J Radiat Oncol Biol Phys 2015;92(1):161?8.
23) Cumberlin RL, Dritschilo A, Mossman KL. Carcinogenic
effects of scattered dose associated with
radiation therapy. Int J Radiat Oncol Biol Phys
1989;17(3):623-9.