2Department of Radiation Oncology, Okmeydanı Training and Research Hospital, İstanbul-Turkey
3Department of Medical Physics, Okmeydanı Training and Research Hospital, İstanbul-Turkey
4Department of Radiation Oncology, Avrupa Şafak Hospital, İstanbul-Turkey DOI : 10.5505/tjo.2018.1870
Summary
OBJECTIVEThe aim of the present study is the dosimetric comparison of intensity-modulated radiation therapy and volumetric arc therapy (VMAT) that are currently applied in the preoperative radiotherapy of locally advanced rectal cancer.
METHODS
Ten patients with locally advanced rectal cancer were recontoured according to defined protocol on
computed tomography simulation that was previously scanned. Dosimetric comparison was performed
for each patient with 7 and 9 fields intensity-modulated radiation therapy and VMAT. Compared dosimetric
parameters were determined as doses of organs at risk, the total duration of treatment, target
coverage, conformity index, homogeneity index, and the total monitor unit (MU).
RESULTS
All plans provided comparable dosimetric parameters for target volumes. Arc plans demonstrated a
statistically significant benefit with lower doses on V15 and Dmean of the small bowel than intensity-modulated
radiation therapy. Arc plans were obviously superior relating to measured volumes of the whole
body, and plans with 7 field had the worst results. In addition, the reduction in total treatment time by
approximately 60% was achieved in arc plans.
CONCLUSION
VMAT with short treatment duration and low MUs can be considered as providing a more comfortable
and qualified treatment.
Introduction
Neoadjuvant chemoradiotherapy (CRT) has become the standard therapy to obtain the desired results in patients with locally advanced (T3/T4) and lymph node involvement (stage II?III) rectal cancer with regard to local control and cure. Many studies have shown the superiority of preoperative radiotherapy in reducing the risk of local recurrence and toxicity compared with postoperative radiotherapy.[1-3] However, acute and chronic intestinal toxicities caused by preoperative treatment are still the most important causes of morbidity.[4]The relationship between specific dose-volume constraints and organ toxicity has been known.[5-6] The small bowel is a radiosensitive organ as acute radiation enteritis occurs in many patients undergoing radiotherapy for rectal cancer. Many studies showed that the incidence of both acute and late effects is directly related to the maximum dose and total volume of irradiated bowel.[7,8] Grade 3-4 acute toxicity was reported in up to 23% of patients treated with preoperative radiotherapy with concurrent chemotherapy, increasing to 37% with doses >50 Gy to the pelvis.[9,10]
Accordingly, highly conformal radiation therapy planning and delivery techniques, such as intensitymodulated radiotherapy (IMRT) and volumetric arc therapy (VMAT), that allows for a reduction of high doses to organs at risk (OARs), without compromising target coverage, are being investigated. Therefore, there are several studies comparing the inverse planning system with different IMRT and VMAT techniques, and the clinical implications of the results are still unclear. [11,12] Thus, the aim of the present study was to compare the OARs sparing without compromising the target coverage among 7 and 9 fields IMRT and doublearc VMAT prospectively.
Methods
Patient GroupsTen patients (5 women and 5 men) with locally advanced rectal cancer treated with the indication of preoperative CRT/radiotherapy in Okmeydanı Training and Research Hospital between 2012 and 2015 were observed. The median age of the patients was 55 (min? max 33?69) years. Tumor length varied between 2 and 10 cm, with median lengths of 6 cm. All patients had stage III (cT3N+) disease.
Monitoring, Target Volume Determination, and
Dose Prescription
All patients were stabilized in a prone position using a
carbon-fiber belly board. The planning computed tomography
(CT) scanned at a slice thickness of 3 mm
was transferred to the Eclipse 10.0 treatment planning
system. Positron emission tomography-CT and/
or magnetic resonance imaging images recorded were
matched using fusion algorithms to determine target
volume. Treatment volumes were recalibrated according
to the Radiation Therapy Oncology Group (RTOG)
consensus of conformal contouring atlas for anorectal cancer published online in 2008.[13] Fullness or empty
bladder was not implemented. The OARs were bladder,
right and left femur heads, and small bowel. The dose
to the OARs at least complied with the following constraints:
bladder ≥65 Gy in ≤50% volume, small bowel
(peritoneal cavity) ≥45 Gy in ≤195 cc volume, and femur
heads ≥40 Gy in ≤10% volume.
Planning Techniques and Objectives
Planning target volumes (PTV1 and PTV2) were
planned using the Eclipse 10.0 treatment planning system
on the Trilogy linac and Millennium 120 MLC system
using the simultaneous single boost method. The
prescribed doses were 45 Gy to the PTV2 and 50.4 Gy
simultaneous to the PTV1 in 25 fractions. Three plans
were performed for each patient, including 7 field IMRT
(IMRT7), 9 field IMRT (IMRT9), and double-arc VMAT
(ARC). The maximum dose rate was optimized to 600
MU/min. 6 MV photons were used in all plans.
Plan optimization is defined as taking 100% of the prescription dose covered by at least 95% of the PTV. The values of D98% (dose received by 98% of the PTV) and D2% (dose received by 2% of the PTV) for PTV were determined as the minimum and maximum doses (Dmean and Dmax) according to the International Commission on Radiation Units and Measurements-83. The conformity of the plans was evaluated with a conformity index (CI) defined as the ratio of the target volume receiving 95% of the prescribed dose divided by the total volume receiving that dose level. The homogeneity of the plans was measured with regard to the homogeneity index (HI), which was expressed as (D2%? D98%)/D50%. The Eclipse system was not able to calculate the estimated treatment time per fraction. Therefore, monitor unit (MU) values were used in VMAT plans to compare treatment times ("beam on"). The duration of treatment was determined by the ratio of the total MU to the maximum dose rate (MU/dose rate). In IMRT plans, "beam on" times were obtained from the system. Plan Quality Assurance (QA) was performed for total treatment periods. Data were obtained using dose?volume histograms (DVHs). Anisotropic Analytical Algorithm (version 10.0.028) was used as the planning algorithm, and Dose Volume Optimizer (version 10.0.028) was used for optimization algorithm.
1. IMRT Plans
The IMRT plans were calculated using seven fixed
gantry angles (0°, 52°, 104°, 154°, 208°, 260°, and 312°)
and nine fixed gantry angles (0°, 41°, 82°, 123°, 164°,
205°, and 328°).
2. VMAT Plans
Each plan with double arc consisted of two complete
arcs set from 181° to 179° and from 179° to 181° (clockwise
and counterclockwise), respectively. The collimator
angles were defined as 30° and 330° for all plans.
Organ at Risk
OAR for each plan was evaluated by the following:
V<12 (volume receiving <12 Gy), V15, Dmin, and Dmax for
small bowel; V30, V40, and Dmean for bladder; D15, V30,
Dmax, and Dmean for each femoral head; and V10, V20, V30,
and V40 for normal tissue that excluded PTV2 from the
whole body (NTV).
Statistical Analysis
All dosimetric results from different irradiation techniques
were compared with each other. Repeated measures analysis of variance was used for comparison of
plans. Bonferroni correction was used for post hoc
analysis. Intraclass correlation coefficient was used to
determine the correlation between measurements. A
p-value of <0.05 was considered statistically significant.
Results
The statistical dosimetric evaluation and comparison of the three planning techniques are listed in Table 1.Table 1: Dosimetric results for PTV and OARs
Target Coverage and Dose Distribution
The mean volume of the PTV was 1452.9±115.1 cc,
the minimum was 286.9 cc, and the maximum was
603.6 cc. For PTV1, IMRT9 achieved better HI than
IMRT7 and ARC (p=0.026). Although D98% was higher
for IMRT9 than for ARC (p=0.001), there were no significant differences between all plans on CI values
(p=0.188). For PTV2, there was no difference for all
the evaluated dosimetric parameters (Table 1). Dose
distibutions of the three planning techniques for two
patients in axial slices are shown in Fig. 1.
Small Bowel and Bladder
The mean volume of the small bowel was 822.2±340.7
(430.2?1394.3) cc. There were no significant differences
between all three plans on V<12, V30, and Dmax. However,
V15 and Dmean were lower for ARC than for IMRT7 and IMRT9, respectively (ARC?IMRT7, p=0.030 and ARCIMRT9,
p=0.035). The volume of the bladder ranged
from 62.6 to 517 cc with a mean of 180.5±129.7 cc. The
results for plans were comparable, but V30 was lower for
IMRT7 than for both IMRT9 and ARC (p=0.031 and
p=0.02, respectively) (Table 1).
Femur Heads
V40 for femur heads in each of three plans were excluded
from the analysis because of detecting 40Gy on
DVHs only linearly. In general, IMRT7 revealed the
highest irradiated volumes, whereas IMRT9 and ARC
could achieve comparably better results (Table 1).
Normal Tissue
V10, V20, V30, and V40 were evaluated for normal tissue
that excluded PTV2 from the whole body (Table 1).
The results for ARC were obviously superior relating
to measured volumes, and IMRT7 plans had the worst
results (ARC
ARC plans had the lowest MU values, as expected
(p=0.01). There was no significant difference between
the "beam on" times. However, when the total treatment
time was considered, the superiority of ARC
plans was observed according to data obtained with
QA. The mean treatment periods were measured as
6.83+0.61 min in IMRT7, 8.21+0.74 min in IMRT9,
and 3.09+0.31 min in ARC.
Discussion
Dosimetric benefits of IMRT and VMAT compared with three-dimensional conformal radiation therapy (3DRT) for preoperative treatment of rectal cancer are well established. These highly conformal radiation therapy planning and delivery techniques are based on the delivery of highly modulated dose fluence from multiple directions to limit high-dose volumes outside the treatment target. In this way, concave/convex isodose lines can be formed. This advantage means a reduction of high doses to OARs, creating lower acute and late toxicity expectations in clinical implication. There are several prospective studies using IMRT/VMAT for preoperative radiotherapy in rectal cancer. However, studies demonstrating clinical benefits are limited to phase I/II, and late toxicity data are few. The primary reason of using these technologies is to decrease acute and late toxicities for treatment tolerability and long-term quality of life. Radiation enteritis is the most common acute toxicity and occurs in many patients undergoing radiotherapy for rectal cancer. Grade 3?4 acute toxicity was reported in up to 23% of patients treated with preoperative CRT, increasing to 37% with doses >50 Gy.[9,10] These data suggested that the small bowel volume receiving 15 Gy (V15) is strongly associated with the degree of toxicity.[9] In addition, Robertson et al.[14] showed that V15, V20, and V25 are associated with grade 3-4 diarrhea. Urbano et al.[15] reported a 64% reduction in intestinal volume by 45-50 Gy with IMRT compared with 3DRT in dosimetric analysis with patients with rectal cancer simulated in the prone position with a full bladder. In their study, three different IMRT schemes, as 5, 7, and 9 fields IMRT, were compared. Although the superiority of IMRT to 3DRT was shown, no significant difference was found in the effect of field count on the irradiated intestinal volume. In our study, although there was a decrease in the average V15 and V30 values in IMRT9 compared with IMRT7 plans, there were no significant differences (V15, p=0.067 and V30, p=0.107). ARC showed superior dosimetric results to IMRT7 on V15 and to IMRT9 on Dmean (p=0.030 and p=0.035, respectively).Moreover, there are several studies that have focused on treatment intensification by using different CRT regimens with the aim of limiting treatment-induced toxicity using IMRT.[16-19] RTOG 0822 that aimed a 12% reduction of grade 2 and over gastrointestinal (GI) toxicity with IMRT applied to neoadjuvant CRT (concurrent capecitabine 825 mg/m2 BID and 5 cycles of oxaliplatin 50 mg/m2 weekly) compared with RTOG 0247 applied with 3DRT showed a 51.5% rate of grade ≥2 GI toxicity, which exceeded the observed rate of 40% in RTOG 0247.[19] Thus, the volume of the bowel receiving low-dose radiotherapy (e.g., 15 Gy) may be more important when using multi-agent chemotherapy, suggesting that low-dose constraints may need to be more compelling to produce a clinically optimal plan.
When the bladder tolerance doses are taken into account, dose prescriptions applied as preoperative for rectal cancer do not mean a significant risk for bladder toxicity. However, a volumetric or dosimetric threshold that can be associated with acute and late side effects in rectal cancer has not been established. Wolff et al. stated in 2011, in that compared proton, VMAT, IMRT, and 3DRT in patients with locally advanced rectal cancer, that only V40 volumes for bladder are statistically significantly higher in IMRT than in VMAT plans.[20] In the same year, a similar comparison was published by Cilla et al.[13] in which V15, V30, V40, V50, V55, and Dmax analyses were performed for the bladder. How ever, PTV1 was defined as 57.5 Gy. Although lower doses were obtained for the bladder in VMAT plans, no significant differences were found. In contrast with the literature, in our study for the bladder, V30 was significantly lower for IMRT7 than for IMRT9 (p=0.031) and ARC (p=0.02). These results could be caused by the used number of segments, different dose intensities on each fields, or prone position.
One of the important parts of pelvic radiotherapy with regard to late toxicity is the femur heads because of its function. Dose?response relationship is not known but is more frequent at higher doses of 40 Gy. In the present study, ARC showed superior dosimetric results to IMRT. In addition, when IMRT plans are assessed within themselves, the superiority of IMRT9 plans is emphasized in all parameters. This may be due to the increased dose intensity compared with IMRT9 and because of non-coplanar beams (104° and 260°) used in IMRT7.
Although IMRT and VMAT have defined dosimetric advantages, clinical reflections have yet to be demonstrated. Both techniques limit the high-dose areas obtained by normal tissues when compared with 3DRT, whereas the low-dose areas increase. This may lead to an increased risk of radiation-related cancer formation due to DNA mutations and carcinogenesis that increase in low- and moderate-dose values. As we assess the dosimetric comparison of normal tissue doses, V20, V30, and V40 volumes were significantly lower in ARC plans (IMRT7>IMRT9>ARC). The number of field was only significant at lower doses (10 Gy), and V10 was better in IMRT7 than in IMRT9 plans (p=0.004 and p<0.01, respectively).
The prolonged treatment increases the uncertainty due to the patient's movement, and it has been stated that IMRT was successful in reducing the volume of irradiated bowel with prone position in many studies.[21,22] Uncertainties during interfraction and intrafraction can cause the target dose to decrease below the desired dose due to sharp dose drops close to large target volumes at IMRT and VMAT. Considering all this, it can be said that VMAT"s most important superiorities against IMRT are short duration of treatment and low MU values. VMAT resulted in a reduction of up to 60% in mean total treatment time (IMRT7 6.83+0.61 min, IMRT9 8.21+0.74 min, and ARC 3.09+0.31 min).
Conclusion
VMAT with short treatment duration and low MU values can be considered as providing a more comfortable and qualified treatment for patients with rectal cancer. The superiority obtained in OAR may not be meaningful because of the uncertainty in clinical manifestations. There is a need for phase III dosimetric studies to be performed with more patients and clinical observation. Peer-review: Externally peer-reviewed.Conflict of Interest: None declared.
Ethics Committee Approval: This study was conducted in accordance with local ethical rules.
Financial Support: None declared.
Authorship contributions: Concept - S.O.; Design - S.O., H.A.; Supervision - S.O., M.Ü.; Materials - S.O., H.A., S.A., Y.S.; Data collection &/or processing - S.O., H.A.; Analysis and/or interpretation - S.O.; Literature search - S.O.; Writing - S.O.; Critical review - S.O., M.Ü.
References
1) Sauer R, Becker H, Hohenberger W, Rödel C, Wittekind
C, Fietkau R, et al.; German Rectal Cancer
Study Group. Preoperative versus postoperative
chemoradiotherapy for rectal cancer. N Engl J Med
2004;351(17):1731-40.
2) Rödel C, Sauer R. Integration of novel agents into
combined-modality treatment for rectal cancer patients.
Strahlenther Onkol 2007;183(5):227-35.
3) Frykholm GJ, Glimelius B, Påhlman L. Preoperative
or postoperative irradiation in adenocarcinoma of the
rectum: final treatment results of a randomized trial
and an evaluation of late secondary effects. Dis Colon
Rectum 1993;36(6):564-72.
4) Kollmorgen CF, Meagher AP, Wolff BG, Pemberton
JH, Martenson JA, Illstrup DM. The long-term effect
of adjuvant postoperative chemoradiotherapy
for rectal carcinoma on bowel function. Ann Surg
1994;220(5):676-82.
5) Huang EH, Pollack A, Levy L, Starkschall G, Dong L,
Rosen I, et al. Late rectal toxicity: dose-volume effects
of conformal radiotherapy for prostate cancer. Int J
Radiat Oncol Biol Phys 2002;54(5):1314-21. 6. Kupelian
PA, Reddy CA, Carlson TP, Willoughby TR.
Dose/volume relationship of late rectal bleeding after
external beam radiotherapy for localized prostate
cancer: absolute or relative rectal volume? Cancer J
2002;8(1):62-6.
7) Tho LM, Glegg M, Paterson J, Yap C, MacLeod A,
McCabe M, et al. Acute small bowel toxicity and
preoperative chemoradiotherapy for rectal cancer:
investigating dose-volume relationships and role
for inverse planning. Int J Radiat Oncol Biol Phys
2006;66(2):505-13.
8) Letschert JG, Lebesque JV, de Boer RW, Hart AA,
Bartelink H. Dose-volume correlation in radiation-related
late small-bowel complications: a clinical study.
Radiother Oncol 1990;18(4):307-20.
9) Letschert JG, Lebesque JV, de Boer RW, Hart AA,
Bartelink H. Dose-volume correlation in radiation-related
late small-bowel complications: a clinical study.
Radiother Oncol 1990;18(4):307-20.
10) Baglan KL, Frazier RC, Yan D, Huang RR, Martinez
AA, Robertson JM. The dose-volume relationship of
acute small bowel toxicity from concurrent 5-FUbased
chemotherapy and radiation therapy for rectal
cancer. Int J Radiat Oncol Biol Phys 2002;52(1):176-83.
11) Kopp RW, Duff M, Catalfamo F, Shah D, Rajecki M,
Ahmad K. VMAT vs. 7-field-IMRT: assessing the dosimetric
parameters of prostate cancer treatment with a
292-patient sample. Med Dosim 2011;36(4):365-72.
12) Lawrie TA, Green JT, Beresford M, Wedlake L, Burden
S, Davidson SE, et al. Interventions to reduce acute and
late adverse gastrointestinal effects of pelvic radiotherapy
for primary pelvic cancers. Cochrane Database
Syst Rev 2018;1:CD012529.
13) Myerson RJ, Garofalo MC, El Naqa I, Abrams RA, Apte
A, Bosch WR, et al. Elective clinical target volumes for
conformal therapy in anorectal cancer: a radiation
therapyoncology group consensus panel contouring
atlas. Int J Radiat Oncol Biol Phys 2009;74(3):824-30.
14) Guerrero Urbano MT, Henrys AJ, Adams EJ, Norman
AR, Bedford JL, Harrington KJ, et al. Intensitymodulated
radiotherapy in patients with locally advanced
rectal cancer reduces volume of bowel treated
to high dose levels. Int J Radiat Oncol Biol Phys
2006;65(3):907-16.
15) Robertson JM, Lockman D, Yan D, Wallace M. The
dose-volume relationship of small bowel irradiation
and acute grade 3 diarrhea during chemoradiotherapy
for rectal cancer. Int J Radiat Oncol Biol Phys
2008;70(2):413-8.
16) Aristu JJ, Arbea L, Rodriguez J, Hernández-Lizoain JL,
Sola JJ, Moreno M, et al. Phase I-II trial of concurrent
capecitabine and oxaliplatin with preoperative intensity-
modulated radiotherapy in patients with locally
advanced rectal cancer. Int J Radiat Oncol Biol Phys
2008;71(3):748-55.
17) Arbea L, Martínez-Monge R, Díaz-González JA,
Moreno M, Rodríguez J, Hernández JL, et al. Fourweek
neoadjuvant intensity-modulated radiation
therapy with concurrent capecitabine and oxaliplatin
in locally advanced rectal cancer patients: a validation
phase II trial. Int J Radiat Oncol Biol Phys
2012;83(2):587-93.
18) Zhu J, Gu W, Lian P, Sheng W, Cai G, Shi D, et al. A
phase II trial of neoadjuvant IMRT-based chemoradiotherapy
followed by one cycle of capecitabine for
stage II/III rectal adenocarcinoma. Radiat Oncol
2013;8:130.
19) Hong TS, Moughan J, Garofalo MC, Bendell J, Berger
AC, Oldenburg NB, et al. NRG Oncology Radiation
Therapy Oncology Group 0822: A Phase 2 Study of
Preoperative Chemoradiation Therapy Using Intensity
Modulated Radiation Therapy in Combination With
Capecitabine and Oxaliplatin for Patients With Locally
Advanced Rectal Cancer. Int J Radiat Oncol Biol
Phys 2015;93(1):29-36.
20) Wolff HA, Wagner DM, Conradi LC, Hennies S,
Ghadimi M, Hess CF, et al. Irradiation with protons
for the individualized treatment of patients
with locally advanced rectal cancer: a planning
study with clinical implications. Radiother Oncol
2012;102(1):30-7.